Simulation::Automate - A Simulation Automation Tool
The set of modules is called Simulation::Automate.
The tool itself is called SynSim, the command synsim.
synsim
a unix-like system
perl 5
gnuplot for postprocessing (optional)
use Simulation::Automate; &synsim();
SynSim is a generic template-driven simulation automation tool. It works with any simulator that accepts text input files and generates text output (and even those that don't. See "EXAMPLES" for special cases). It executes thousands of simulations with different input files automatically, and processes the results. Postprocessing facilities include basic statistical analysis and automatic generation of PostScript plots with Gnuplot. SynSim is entirely modular, making it easy to add your own analysis and postprocessing routines.
tar -zxvf Simulation-Automate-0.9.5.tar.gz
This installation procedure will install the Simulation::Automate modules in a directory of your choice, and create a template directory structure for your SynSim project.
In the main directory of the distribution (i.e. the directory which contains the file local_install.pl), type:
local_install.pl
perl local_install.pl
The install script asks for the name of the directory in which it will put SynSim:
Local SinSym directory? [/local/home/wim/SynSim]:
If you enter just a name, the installer assumes that the directory is in your home directory. If you want to install SynSim outside your home directory, enter a full path.
The install script asks for the name of directory where you will run SynSim:
Simulation project directory? [SynSimProject]:
This directory is a subdirectory of the local SynSim directory.
That's it. Now you can go to your project directory and run the synsim script as a test:
./synsim
This will run a simple test. If the installation was succesful, it will display the follwing message:
SynSim Installation Test Simulation::Automate version 0.9.6 installed locally in /home/wim/SynSim/Test Finished SynSim run
This is the typical Makefile.PL-driven installation procedure. It is only required for system-wide installation, but it works for local installation as well.
cd Simulation-Automate-0.9.5 perl Makefile.PL
make
make test
This requires you to be root:
su make install
or
sudo make install
This does not require you to be root:
make localinstall
perl -e "use Simulation::Automate; &Simulation::Automate::localinstall();"
SynSim is the name for the tool contained in Simulation::Automate. This step creates the directory structure for your simulations:
make setup or perl -e "use Simulation::Automate; &Simulation::Automate::setup();"
The archive structure is as follows:
README Makefile.PL Automate.pm local_install.pl Automate/ Remote.pm PostProcLib.pm Analysis.pm Dictionary.pm PostProcessors.pm eg/ synsim synsim.data ErrorFlags.data Histogram.data SweepVar.data Expressions.data gnuplot.data SOURCES/ bufsim3.cc MersenneTwister.h TEMPLATES/ test.templ DEVTYPES/ SIMTYPES/ bufsim3.templ PLUGINS/
To configure SynSim for use with your simulator, you must create a set of files in your SynSim project directory structure. This paragraph gives an overview of the different types of files and their place in the SynSim project directory structure.
You can create a SynSim directory structure with perl local_install.pl or make setup (see "INSTALLATION" for details). If you already have an existing project, you can do this:
make setup
Create a new project directory:
mkdir NewProject
Copy the synsim script from the old project:
cp oldProject/synsim NewProject
Go to the NewProject directory and run synsim with the -D option:
NewProject
-D
cd NewProject ./synsim -D
If you want to create it manually, this is the structure. Directories between square brackets are optional.
YourProject/ synsim YourDataFile.data [SOURCES/] TEMPLATES/ YourSimTempl.templ [DEVTYPES/] [SIMTYPES/] [PLUGINS/] [Simulation/SynSim/] [Dictionary.pm] [PostProcessors.pm]
The synsim script is the actual script that runs the DOE. It contains the 2 lines from the "SYNOPSIS". The local Simulation/Automate modules are only required if you want to customize the postprocessing.
The directory SOURCES/ is optional. It should contain all files which are required "read-only" by your simulator (e.g. header files, library files, wrappers).
Template files are files in which simulation variables will be substituted by their values to create the input file for your simulator. They must be stored in the TEMPLATES/ directory, and have by convention the extension .templ.
.templ
SynSim variable format
The template file format is free, but the variables to be substituted by SynSim must be in uppercase and start with an underscore:
Examples:
_VAR1 _LONG_VARIABLE_NAME
To create a template file, start from an existing input file for your simulator. Replace the values of the variables to be modified by SynSim by a SynSim variable name (e.g. var1 = 2.5 => var1 = _VAR1). Put the template files in TEMPLATES.
Note: Relative paths to source files
SynSim creates a run directory ath the same level as the SOURCES and TEMPLATES directories. All commands (compilations etc.) are executed in that directory. As a consequence, paths to source files (e.g. header files) should be "../SOURCES/sourcefilename".
../SOURCES/
Note: The DEVTYPES/ and SIMTYPES/ subdirectories
SynSim can create an input file by combining two different template files, generally called device templates and simulation templates. This is useful in case you want to run different types of simulations on different devices, e.g. DC analysis, transient simulations, small-signal and noise analysis on 4 different types of operational amplifiers. In total, this requires 16 different input files, but only 8 different template files (4 for the simulation type, 4 for the device types). If you want to use this approach, device templates should go in TEMPLATES/DEVTYPES/ and simulation templates in TEMPLATES/SIMTYPES/. SynSim will check both directories for files as defined in the datafile. If a matching file is found in DEVTYPES, it will be prepended to the simulation template from SIMTYPES.
The datafile is the input file for synsim. It contains the list of simulation variables and their values to be substituted in the template files, as well as a number of configuration variables. See "DATAFILE DESCRIPTION" for more information.
The PostProcessing.pm module contains routines to perform postprocessing on the simulation results (e.g. plotting, statistical analysis, etc). A number of generic routines are provided, as well as a library of functions to make it easier to develop your own postprocessing routines. See "POSTPROCESSING" for a full description).
Before the raw data are sent to the postprocessor, it is possible (and very easy) to preprocess the raw data. See "PREROCESSING" for more details.
Custom postprocessing and preprocessing routines can either be stored in the PLUGINS/ directory (preferred) or directly in the local PostProcessing.pm module (more intended for modified versions of the generic routines).
The Dictionary.pm module contains descriptions of the parameters used in the simulation. These descriptions are used by the postprocessing routines to make the simulation results more readable. See "DICTIONARY" for a full description).
The datafile defines which simulations to run, with which parameter values to use, and how to run the simulation. By convention, it has the extension .data.
.data
The datafile is a case-sensitive text file with following syntax:
Comments are preceded by '#'. Comments, blanks and empty lines are ignored
Parameters (simulation variables) are in UPPERCASE with a leading '_', and must be separated from their values with a '='.
Keywords (configuration variables) are in UPPERCASE, and must be separated from their values with a ':'.
Lists of values have one or more items. The list separator is a comma ','.
Example:
_PAR1 = 1,1,2,3,5,8,13
If a list has 3 elements START,STOP,STEP, then if possible this list will be expanded as a for-loop from START to STOP with step STEP.
_NBUFS = 16,64,8 # from 16 to 64 in steps if 8: 16,24,32,40,48,56,64
These must be lines containing only the simulation type
The main purpose of the datafile is to provide a list of all variables and their values to be substituted in the template files.
A simulation will be performed for every possible combination of the values for all parameters.
_PAR1 = 1,2 _PAR2 = 3,4,5
defines 6 simulations: (_PAR1,_PAR2)=(1,3),(1,4),(1,5),(2,3),(2,4),(2,5)
Simulation results for all values in ','-separated list are stored in a separate files.
It is possible (See the keyword GROUP under "Configuration variables") to define groups of variables. For every parameter in a group, the value list must have the same number of items. The values of all variables at the same position in the list will be used.
GROUP: _PAR1,_PAR2 _PAR1 = 0;1;2;4 _PAR2 = 3;4;5;6
defines 4 simulations: (_PAR1,_PAR2)=(0,3);(1,4);(2,5);(4,6)
A number of configuration variables ("keywordsw) are provided to configure SynSim's behaviour. There is no mandatory order, but they must appear before the simulation variable. For the default order, see the "EXAMPLES". In alphabetical order, they are:
Alternative names: ANALYSIS_TEMPLATE, ANATEMPL
Name of the routine to be used for the result analysis (postprocessing). This routine must be defined in PostProcessors.pm or in a file in the PLUGINS/ directory. A number of generic routines are provided, see "POSTPROCESSING".
The command line for the program that runs the input file, i.e. the simulator command (default: perl). SynSim looks for the words INPUTFILE and <OUTPUTFILE> and substitutes them with the actual file names.
yoursim1 -i INPUTFILE -o OUTPUTFILE yoursim2 INPUTFILE > OUTPUTFILE
The name of the device on which to perform the simulation. If defined, SynSim will look in TEMPLATES/DEVTYPES for a file with TEMPL and DEVTYPE, and prepend this file to the simulation template before parsing. This keyword can take a list of values
Extension of input file (default: .pl)
Some simulators expect a particular extension for the input file. This can be specified with the keyword EXT.
This keyword can be used to change the default behaviour of creating nested loops for every parameter. It takes as argument a list of parameters. The behaviour for grouped parameters is to change at the same time. All parameter lists in the group must have the same number of values. More than one group can be created.
# First group: 2 parameters, each 4 values GROUP: _PAR_A1,_PAR_A2 # Second group: 3 parameters, each 3 values GROUP: _PAR_B1,_PAR_B2,_PAR_B3 # SynSim will run 4*3 simulations (default without groups would be 16*27) _PAR_A1 = 0;1;2;4 _PAR_A2 = 3;4;5;6 _PAR_B1 = -1;1;2 _PAR_B2 = 3;4;7 _PAR_B3 = 3;6;15
If the value of INCLUDE is an exisiting filename, this datafile will be included on the spot.
The name of the variable to normalise the results with. The results will be divided by the corresponding value of the variable.
A Perl regular expression to filter the output of the simulation (default : .*). Tis is very usefull for very verbose simulators. The results file will only contain the filtered output.
The name of a function which modifies @results before the actual postprocessing. Very usefull to "streamline" the raw results for postprocessing.
@results
Alternative names: SIMULATION, SIMTEMPL, SIMTYPE
The name of the template file, with or without extension. By convention, this is the same as the type of simulation to be performed. If no extension is given, SynSIm checks for a TEMPLEXT keyword; if this is not defined, the extenstion defaults to .templ. SynSim will look for the template file in TEMPLATES/ and TEMPLATES/SIMTYPES/.
Note: Multiple simulation types
The value of SIMULATION can be a ','-separated list. In this case, SynSim will use the datafile for multiple types of simulations. Every item in the list can be used as a section header, demarkating a section with variables particular to that specific simulation.
Extension of template files (default: .templ)
The title of the DOE. This title is used on the plots, but typically it is the first line of the datafile and describes the DOE.
Alternative name: SWEEPVAR
The name of the variable to be sweeped. Mandatory if the postprocessing routine is XYPlot.
The number of times the simulation has to be performed. For statistical work.
The column in the output file which contains the X-values.
Alternative name: DATACOL
The column in the output file which contains the simulation results (default: 2). Mandatory if using any of the generic postprocessing routines.
Variables to allow more flexibility in the customization of the plots. They are identical to the corresponding (lowercase) gnuplot keywords, see the gnuplot documentation for details. The most commonly used, XLABEL and YLABEL are the X and Y axis labels. LOGSCALE is either X, Y or XY, and results in a logarithmic scale for the chosen axis.
gnuplot
The SynSim datafile has support for expressions, i.e. it is possible to express the value list of a variable in terms of the values of other variables.
# average packet length for IP dist _MEANPL = ((_AGGREGATE==0)?2784:9120) # average gap width _MEANGW= int(_MEANPL*(1/_LOAD-1)) # average load _LOAD = 0.1;0.2;0.3;0.4;0.5;0.6;0.7;0.8;0.9 # aggregate _AGGREGATE = 0,12000
The variables used in the expressions must be defined in the datafile, although not upfront. Using circular references will not work. The expression syntax is Perl syntax, so any Perl function can be used. Due to the binding rules, it is necessary to enclose expressions using the ternary operator ?: with brackets (see example).
The SynSim script must be executed in a subdirectory of the SynSim directory which contains the TEMPLATES subdir and the datafile (like the Example directory in the distribution).
The command line is as follows:
./synsim [-h -D -i -p -P -v -N ] [datafile] [remote hostname]
The synsim script supports following command line options:
none: defaults to -f synsim.data -D : Create an empty SynSim directory structure in the current directory. -v : 'verbose'. Sends simulator output to STDOUT -i : interactive. Calls gv or ggv to display a plot of the results. Implies -p -v. -p : plot. This enables generation of postscript plots via gnuplot. A postprocessing routine is required to generate the plots. -P : Plot. This option can be used to display plots created with -p. -w : 'warnings'. Show warnings about undefined variables. -N : 'No simulations'. Performs only postprocessing. -h, -? : short help message
If [remote hostname] is provided, SynSim will try to run the simulation on the remote host.
The current implementation requires:
-ssh access to remote host
-scp access to remote host
-rsync server on the local host
-or,alternatively, an NFS mounted home directory
-as such, it will (probably) only work on Linux and similar systems
Postprocessing of the simulation results is handled by routines in the PostProcessors.pm module. This module uses the PostProcLib.pm and optionally Dictionary.pm and Analysis.pm.
PostProcessors.pm
PostProcLib.pm
Dictionary.pm
Analysis.pm
SynSim comes with a number of generic postprocessing routines.
Required configuration variables: XVAR
XVAR
Creates a plot using XVAR as X-axis and all other variables as parameters. This routine is completely generic.
Required configuration variables: XVAR,CONDVAR and CONDITION.
CONDVAR
CONDITION
Creates a plot using SETVAR as X-axis; XVAR is checked against the condition COND (or CONDITION). The first value of CONDVAR that meets the condition is plotted. All other variables are parameters. This routine is completely generic.
SETVAR
COND
Required configuration variables: XVAR, NRUNS
NRUNS
Optional configuration variables: NSIGMAS
NSIGMAS
Creates a plot using XVAR as X-axis and all other variables as paramters. Calculates average and 95% confidence intervals for NRUNS simulation runs and plots error flags. This routine is fully generic, the confidence interval (95% by default) can be set with NSIGMAS. See eg/ErrorFlags.data for an example datafile.
Required configuration variables: NBINS
NBINS
Optional configuration variables: BINWIDTH, MIN, MAX
BINWIDTH
MIN
MAX
Creates a histogram of the simulation results. This requires the simulator to produce raw data for the histograms in a tabular format. When specifying logscale X or XY for the plot, the histogram bins will be logarithmic. See eg/Histogram.data for an example. The number of bins in the histogram must be specified via NBINS. The width of the bins can be set with BINWIDTH, in which case MIN and MAX will be calculated. When MIN or MAX are set, BINWIDTH is calculated. It is possible to specify either MIN or MAX, the undefine value will be calculated.
All of the above routines have hooks for simple functions that modify the @results array. To call these functions, include them in the datafile with the PREPROCESSOR variable. e.g:
PREPROCESSOR
PREPROCESSOR : modify_results All functions must be put in the PLUGINS folder or in the PostProcessors.pm module, and the template could be like this: sub modify_results { foreach my $results_line (@results) { #Do whatever is required } } # End of modify_results
The Dictionary.pm module contains descriptions of the parameters used in the simulation. These descriptions are used by the postprocessing routines to make the simulation results more readable. The dictionary is stored in an associative array called make_nice. The description of the variable is stored in a field called 'title'; Descriptions of values are stored in fields indexed by the values.
make_nice
Following example illustrates the syntax:
# Translate the parameter names and values into something meaningful %Dictionary::make_nice=( _BUFTYPE => { title=>'Buffer type', 0=>'Adjustable', 1=>'Fixed-length', 2=>'Multi-exit', }, _YOURVAR1 => { title=>'Your description for variable 1', }, _YOURVAR2 => { title=>'Your description for variable 2', 'val1' => 'First value of _YOURVAR2', 'val3' => 'Second value of _YOURVAR2', }, );
SynSim creates a run directory {SIMTYPE}-[datafile without .data]. It copies all necessary template files and source files to this directory; all output files are generated in this directory.
{SIMTYPE}-
SynSim generates following files:
Output files for all simulation runs.
The names of these files are are {SIMTYPE}_C[counter]_[simulation number].out
{SIMTYPE}_C
.out
counter is increased with every new combination of variables except for XVAR.
simulation number is the position of the value in the XVAR- list.
Combined output file for all values in a ';'-separated list.
The names of these files are are {SIMTYPE}_C[counter]_.out
_.out
counter is increased with every new combination of variables in ','-separated lists.
Only the lines matching /OUTPUT_FILTER_PATTERN/ (treated as a Perl regular expression) are put in this file.
/OUTPUT_FILTER_PATTERN/
Combined output file for all values in a ';'-separated list, with a header detailing all values for all variables.
The names of these files are are {SIMTYPE}_C[counter].res,
.res
Only the lines in the .out files matching /OUTPUT_FILTER_PATTERN/ (treated as a Perl regular expression) are put in this file.
Separate input files for every item in a ';'-separated list.
The names of these files are are {SIMTYPE}_[simulation number].{EXT}
{SIMTYPE}_
.{EXT}
simulation number is the position of the value in the list.
These files are overwritten for every combination of variables in ','-separated lists.
In a lot of cases you will want to create your own postprocessing routines. First of all, it is important to understand the SynSim output, so make sure you have read "OUTPUT FILES". Apart from that, there is a very simple API.
All variables from the datafile are exported in a hash called %simdata
%simdata
The value list for every variable is a Perl list. This means that you can access the values like this:
my @importantvars = @{$simdata{_VAR1}}
my $importantvar = $simdata{_VAR1}[0]
The same holds for configuration variables, but in general they only have a single value, so:
my $x_variable = $simdata{XVAR}
Easy-typing names
Furthermore, every variable can be accessed using a short name. Instead of
$simdata{_VAR}
you can use
$_var
This is especially handy for configuration variables, e.g.
$plotstyle
instead of
$simdata{PLOTSTYLE}
Current set of values for the DOE
The current set of values for the DOE is available in the hash %current_set_vals. The keys are the variable names, the values the current value for the variable.
%current_set_vals
Example: A simple DOE with 2 variables.
_VAR1=1,2,3 _VAR2=3,4
This DOE has 6 sets. After the fourth run, the values of the set will be:
$current_set_vals{_VAR1}==2 $current_set_vals{_VAR1}==4
The current set is also available in string format through $current_set_str:
$current_set_str
$current_set_str eq '_VAR1-2-_VAR2-4'
This is useful because this string is part of the name of the results file.
If the configuration variable SETVAR is defined, there is an additional string $current_set_except_setvar_str, which contains the current set except the SETVAR. This is usefull for conditional postprocessing, see e.g. CondXYPlot in PostProcessors.pm.
$current_set_except_setvar_str
Raw results
The raw results of the last simulation run are available in the array @results. Every element in this array is identical to the corresponding line in the output file for the given simulation run.
It is also possible to access the results files: $results_file_name contains the filename of the current results file, and @all_results_file_names is a list of all results files so far.
$results_file_name
@all_results_file_names
Deciding when to call the postprocessor.
SynSim allows to call your postprocessing routine after every run. However, postprocessing generally only makes sense at certain points in the execution of the DOE. SynSim provide two variables: $last, which indicates the end of a sweep, $verylast which indicates the end of the DOE.
$last
$verylast
In summary, following variables are exported:
%simdata # contains all datafile variables #and their values/value lists @results # memory image of the results file %current_set_vals # values for the current set $current_set_str # same in string format $current_set_except_setvar_str $results_file_name @all_results_file_names $last # indicates end of a sweep $verylast # indicates end of the DOE
An example of how all this is used:
sub YourRoutine { ## Define your own variables. ## As every variable can have a list of values, ## $simdata{'_YOURVAR1'} is an array reference. my $yourvar=${$simdata{'_YOURVAR1'}}[0]; my @sweepvarvals=@{$simdata{$sweepvar}}; ## $verylast indicates the end of all simulations if(not $verylast) { ## what to do for all simulations ## $last indicates the end of a sweep if($last) { # Do something at the end of every sweep } # if last } else { ## On the very last run, collect the results into one nice plot &gnuplot_combined($firstplotline,$plotlinetempl); } } #END of YourRoutine()
A module for basic statistical analysis is also available (Analysis.pm). Currently, the module provides 2 routines:
To calculate average, standard deviation, min. and max. of a set of values.
Arguments:
$file: name of the results file. The routine requires the data to be in whitespace-separated columns.
$file
$par: Determines if the data will be differentiated before processing ($par='DIFF') or not (any other value for $par). Differentiation is defined as subtracting the previous value in the array form the current value. A '0' is prepended to the array to avoid an undefined first point.
$par
$datacol: column to use for data
$datacol
$title: optional, a title for the histogram
$title
$log: optional, log of values before calculating histogram or not ('LOG' or '')
$log
Use: my $file="your_results_file.res"; my $par='YOURPAR'; my $datacol=2; my %stats=%{&calc_statistics($file,[$par, $datacol])};
my $avg=$stats{$par}{AVG}; # average my $stdev=$stats{$par}{STDEV}; # standard deviation my $min=$stats{$par}{MIN}; # min. value in set my $max=$stats{$par}{MAX}; # max. value in set
To build histograms. There are 3 extra arguments:
$nbins: number of bins in the histogram $min: force the value of the smallest bin (optional) $max: force the value of the largest bin (optional)
use: my $par='DATA'; my %hists=%{&build_histograms("your_results_file.res", [$par,$datacol],$title,$log,$nbins,$min,$max)};
NOTE: Because the extra arguments are last, the $title and $log arguments can not be omitted. If not needed, supply ''.
Here are some examples of how to use SynSim for different types of simulators.
Normal use: spice -b circuit.sp > circuit.out
With SynSim:
Copy circuit.sp to TEMPLATES/SIMTYPE/circuit.templ Replace all variable values with SynSim variable names.
e.g. a MOS device line in SPICE:
M1 VD VG VS VB nch w=10u l=10u
becomes
M1 VD VG VS VB _MODEL w=_WIDTH l=_LENGTH
TITLE: MOS drain current vs. length SIMTYPE : circuit COMMAND : spice -b inputfile > outputfile # Required for postprocessing OUTPUT_FILTER_PATTERN : Id # keep only the drain current on the output file ANALYSIS_TEMPLATE : SweepVar # default template for simple sweep SWEEPVAR : _L # we sweep the length, the other variables are parameters DATACOL: 2 # first col is the name _L = 1u,2u,5u,10u,20u,50u _W = 10u,100u _MODEL = nch
There are more possible keywords, cf. "DATAFILE DESCRIPTION".
./synsim -p -i -v -f IDvsL.data -p to create plots -i means interactive, so the plots are displayed during simulation -v for verbose output -f because the filename is not the default name
SynSim will run 12 SPICE simulations and produce 1 plot with all results.
All results are stored in the run directory, in this case:
circuit-IDvsL
Normal use: simplesim -a50 -b100 -c0.7
Output is saved in out.txt.
As simplesim does not take an input file, we create a wrapper simplesim.templ in TEMPLATES/SIMTYPE. This file is actually a template for a simple perl script:
system("simplesim -a_VAR1 -b_VAR2 -c_VAR3"); system("cp out.txt $ARGV[0]");
TITLE: simplesim test SIMTYPE : simplesim COMMAND : perl inputfile outputfile
./synsim -f test.data
SynSim will run without any messages and produce no plots.
simplesim-test
Normal use: Modify values for #if and #ifdef constants in the header file; then compile and run.
e.g.:
vi bufsim3.h g++ -o bufsim3 bufsim3.cc ./bufsim3 > outputfile
As bufsim3 does not take an input file, we create a wrapper bufsim3.templ in TEMPLATES/SIMTYPE. This file is actually a template for a perl script that writes the header file, compiles and runs the code:
open(HEADER,">bufsim3.h"); print HEADER <<"ENDH"; #define NBUFS _NBUFS #define NPACKETS _NPACK #AGGREGATE _AGGREGATE ENDH close HEADER; system("g++ -o bufsim3 bufsim3.cc"); system("./bufsim3 $ARGV[0]");
TITLE: bufsim3 test (_NBUFS, _NPACK) # will be substituted by the values SIMTYPE : bufsim3 COMMAND : perl inputfile outputfile
./synsim -w -v -f Aggregate.data
SynSim will run verbose and flag all variables not defined in the datafile.
bufsim3-Aggregate
Normal use: spectre circuit.scs -raw circuit.raw
Copy circuit.scs to TEMPLATES/SIMTYPE/circuit.templ Replace all variable values with SynSim variable names.
The .raw file is a binary file, so it should not be touched. SynSim creates output files with extension .out, and combines these with the headers etc. (cf. "OUTPUT FILES"). By keeping the extension .raw, the simulator output files will not be touched.
In the datafile:
TITLE: Spectre simulation with SPF output EXT: .scs COMMAND: spectre inputfile -raw outputfile.raw > outputfile
SynSim will process outputfile, but not outputfile.raw.
outputfile
outputfile.raw
To access the binary files, you will have to write your own postprocessing routines. Most likely they will rely on an external tool to process the binary data. The files will be found in the run directory, and have names as described in "OUTPUT FILES", with the extra extension .raw.
If the simulator command line does not follow the format required by SynSim, a simple shell or perl wrapper is enough to make SynSim understand it. The wrapper script must be stored under SOURCES/; it should be written such that all relative paths are correct when it is executed under SOURCES/. That is because SynSim runs in a subdirectory fo the project directory. This means that, if the command line contains relative paths to a subdirectory, these paths must be prepended with '../'.
$ simulator INPUTFILE OUTPUTFILE $ simulator --o OUTPUTFILE INPUTFILE $ simulator -i INPUTFILE > OUTPUTFILE $ simulator < INPUTFILE > OUTPUTFILE
$ simulator sim.conf > sim.out
Wrapper:
$ simulator_wrapper.sh INPUTFILE > OUTPUTFILE
The file simulator_wrapper.sh contains 2 lines:
simulator_wrapper.sh
mv $1 sim.conf simulator sim.conf
$ simulator INPUTFILE
The outputfile is called output.txt.
output.txt
$ simulator_wrapper.sh INPUTFILE OUTPUTFILE
simulator $1 mv output.txt $2
$ simulator ../Config/INPUTFILE > OUTPUTFILE
The Config directory is in this case at the same level of project directory.
The file simulator_wrapper.sh contains 2 lines. Note the '../' prepended to the paths:
cp $1 ../../Config simulator ../../Config/INPUTFILE
$ simulator INPUTFILE OUTPUTFILE
The OUTPUTFILE is generated in the Results subdirectory.
OUTPUTFILE
The file simulator_wrapper.sh contains 2 lines. Note the '../' prepended to the path:
simulator $1 $2 cp ../Results/$2 .
$ simulator -a50 -b100 -c0.7
In this case, there is no actual wrapper script. We will create a simple shell script simulator.templ in TEMPLATES/. This script will act as the input file.
$ bash INPUTFILE OUTPUTFILE
We need the explicit call to bash because the INPUTFILE does not have the -x flag set.
The file simulator.templ in TEMPLATES/ contains 2 lines:
simulator -a_VAR1 -b_VAR2 -c_VAR3 cp out.txt $1
SynSim will create simulator.sh from this template file, and then will call bash to execute this shell script.
$ simulator config.in topo.in > out.res
$ perl INPUTFILE OUTPUTFILE
Again, there is no actual wrapper script. The INPUTFILE template is in this case a perl script which contains itself templates for both input files. The script will create both input files, then run the simulator.
INPUTFILE
A possible implementation of simulator.templ:
#!/usr/bin/perl #Template for simulator with multiple input files my $config_templ=<<"ENDCONF"; /* This is the config.in template */ int var1 = _VAR1; ... ENDCONF my $topo_templ=<<"ENDTOPO"; ;;This is the topo.in template var2 = _VAR2 ... ENDTOPO open CONF,">config.in"; print CONF $config_templ; close CONF; open TOPO, ">topo.in"; print TOPO $topo_templ; close TOPO; system("simulator config.in topo.in > $ARGV[0]"); #END of simulator.templ
SynSim will create simulator.pl and then will call perl to run the script
simulator.pl
perl
This module is still Alpha, a lot of work remains to be done to make it more user-friendly. The main tasks is to add a GUI. A prototype can be found on my web site, it is already useful but too early to include here. The next version will also make it easier to create your own postprocessing routines.
Wim Vanderbauwhede <wim\x40motherearth.org>
Copyright (c) 2000,2002-2003 Wim Vanderbauwhede. All rights reserved. This program is free software; you can redistribute it and/or modify it under the same terms as Perl itself.
gnuplot http://www.ucc.ie/gnuplot/gnuplot.html
To install Simulation::Automate, copy and paste the appropriate command in to your terminal.
cpanm
cpanm Simulation::Automate
CPAN shell
perl -MCPAN -e shell install Simulation::Automate
For more information on module installation, please visit the detailed CPAN module installation guide.